VDE 0207 CY PVC YSLCY CY LSZH HSLCH Control Cable

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

CY Cable is used in applications requiring interference-free transmission due to their multi-core flex, tinned copper wire braid (TCWB), and polyethylene terephthalate (PET) separator, which protect it from external electromagnetic influences which could degrade accurate signal transmission. The CY cable's TCWB and PET also provide protection against light mechanical stress.

Performance

Voltage Rating:
300/500V

Temperature Rating:
Fixed: -40°C to +80°C
Flexed: -5°C to +70°C

Minimum Bending Radius
Fixed: 6 x overall diameter
Flexed: 15 x overall diameter

Feature:
High oil-resistance,Abrasion and notch-resistant,EMC-compliant

Flame Retardant:
according to IEC/EN 60332-1-2 Standard

Construction

Conductor:
Class 5 flexible plain copper

Sheath:

Veriflex CY LSZH cable

Veriflex CY PVC cable

HSLH-OZ

LSZH sheathed cable with black numbered cores

YSLY-OZ

PVC sheathed cable with black numbered cores

HSLH-JZ

LSZH sheathed cable with black numbered cores and G/Y earth

YSLY-JZ

PVC sheathed cable with black numbered cores and G/Y earth

HSLH-OB

LSZH sheathed cable with coloured cores

YSLY-OB

PVC sheathed cable with coloured cores

HSLH-JB

LSZH sheathed cable with coloured cores including G/Y earth

YSLY-JB

PVC sheathed cable with coloured cores including G/Y earth

Core identification:
Single core: blue
2 core: brown & blue
3 core: brown, blue & green/yellow
4 core: brown, grey, black & green/yellow
5 core: brown, blue, grey, black & green/yellow
7 core and above: black cores with white number inc Green/Yellow

DIN-VDE-0207-CY-PVC-YSLCY-CY-LSZH-HSLCH-Control-Cable-(2)

1. Fine-stranded bare copper
2. Core insulation of halogen-free, cross-linked polyolefin copolymere
3. Wrapped in a plastic foil
4. Screen of tinned copper wire braiding
5. Oouter sheath of halogen-free, cross-linked polyolefin copolymere, grey

Cable Marking and Packing Materials

Cable Marking:
printing, embossing, engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Standard

VDE 0207 Standard

CY PVC (YSLCY) Control Cable Physical Performance

NO. OF CORES NOMINAL CROSS SECTIONAL AREA NOMINAL THICKNESS OF INSULATION NOMINAL THICKNESS OF OUTER SHEATH NOMINAL OVERALL DIAMETER NOMINAL  WEIGHT
-  mm2 mm  mm mm  kg/km
2 0.5 0.4 0.8 5.4 41
2 0.75 0.4 0.9 6.1 52
2 0.4 0.9 6.5 60
2 1.5 0.4 0.9 7.1 74
3 0.5 0.4 0.8 5.8 51
3 0.75 0.4 0.9 6.4 65
3 1 0.4 0.9 6.8 76
3 1.5 0.4 0.9 7.5 98
3 2.5 0.5 1 9 146
4 0.5 0.4 0.8 6.2 64
4 0.75 0.4 0.9 6.9 82
4 0.4 0.9 7.4 96
4 1.5 0.4 0.9 8.1 122
4 2.5 0.5 1.1 10 190
4 4 0.6 1.2 11.9 283
4 6 0.65 1.3 13.5 386
4 10 0.75 1.5 17.1 630
4 16 0.75 1.6 20.4 910
4 25 0.9 1.8 24.4 1364
4 35 0.95 1.9 28 1814
5 0.5 0.4 0.8 6.7 77
5 0.75 0.4 0.9 7.4 97
5 1 0.4 0.9 8 116
5 1 0.4 1 9 152
5 2.5 0.5 1.1 10.8 228
5 4 0.6 1.2 12.9 332
5 6 0.65 1.3 14.8 457
5 10 0.75 1.5 18.7 749
5 16 0.75 1.7 22.6 1125
5 25 0.9 1.9 27 1683
7 0.5 0.4 0.8 7.2 93
7 0.75 0.4 0.9 8 121
7 1 0.4 1 8.8 148
7 1.5 0.4 1 9.7 191
7 2.5 0.5 1.1 11.7 290
12 0.5 0.4 1 9.6 154
12 0.75 0.4 1 10.4 193
12 1 0.4 1.1 11.4 236
12 1.5 0.4 1.2 12.9 315
18 0.75 0.4 1.2 12.4 281
18 1 0.4 1.2 13.4 339
18 1.5 0.4 1.3 15.1 452
25 0.75 0.4 1.3 14.8 331
25 1 0.4 1.3 16 461
25 1.5 0.4 1.4 18.1 616

Electrical Performance

NOMINAL CROSS SECTIONAL AREA CURRENT CARRYING CAPACITES 30°C CONTINOUS LOADING MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C
mm2 A ohms/km
0.5 9 39
0.75 12 26
1 15 19.5
1.5 18 13.3
2.5 26 7.98
4 34 4.95
6 44 3.3
10 61 1.91
16 82 1.21
25 108 0.78
35 135 0.554

CY LSZH (HSLCH) Control Cable Physical Performance

NO. OF CORES NOMINAL CROSS SECTIONAL AREA NOMINAL THICKNESS OF INSULATION NOMINAL THICKNESS OF OUTER SHEATH NOMINAL OVERALL DIAMETER NOMINAL  WEIGHT
-  mm2 mm  mm mm  kg/km
2 0.5 0.4 0.6 5 35
2 0.75 0.4 0.6 5.5 45
2 1 0.4 0.7 6.1 56
2 1.5 0.4 0.7 6.7 69
3 0.5 0.4 0.6 5.4 48
3 0.75 0.4 0.7 6 61
3 1 0.4 0.7 6.4 71
3 1.5 0.4 0.7 7.1 90
3 2.5 0.5 0.8 8.6 136
4 0.5 0.4 0.7 6 61
4 0.75 0.4 0.7 6.5 75
4 1 0.4 0.7 7 89
4 1.5 0.4 0.7 7.7 114
4 2.5 0.5 0.8 9.4 173
4 4 0.6 1 11.5 260
4 6 0.65 1.1 13.1 358
4 10 0.75 1.3 16.7 593
4 16 0.75 1.5 19 852
4 25 0.9 1.6 23.5 1274
4 35 0.95 1.7 26.9 1686
5 0.5 0.4 0.7 6.5 73
5 0.75 0.4 0.7 7 89
5 1 0.4 0.7 7.6 107
5 1.5 0.4 0.8 8.6 142
5 2.5 0.5 0.9 10.4 216
5 4 0.6 1.1 12.7 325
5 6 0.65 1.2 14.6 449
5 10 0.75 1.4 18.5 738
5 16 0.75 1.5 20.9 1050
5 25 0.9 1.7 26.1 1588
7 0.5 0.4 0.7 7 89
7 0.75 0.4 0.7 7.6 112
7 1 0.4 0.8 8.4 139
7 1.5 0.4 0.8 9.3 180
7 2.5 0.5 1 11.5 283
12 0.5 0.4 0.8 9.2 143
12 0.75 0.4 0.8 10 181
12 1 0.4 1 11.2 230
12 1.5 0.4 1.1 12.7 307
18 0.75 0.4 1.1 12.2 274
18 1 0.4 1.1 13.2 331
18 1.5 0.4 1.2 14.9 443
25 0.75 0.4 1.2 14.6 367
25 1 0.4 1.2 15.8 444
25 1.5 0.4 1.3 17.9 596

Electrical Performance

NOMINAL CROSS SECTIONAL AREA CURRENT CARRYING CAPACITES 30°C CONTINOUS LOADING MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C
mm2 A ohms/km
0.5 9 39
0.75 12 26
1 15 19.5
1.5 18 13.3
2.5 26 7.98
4 34 4.95
6 44 3.3
10 61 1.91
16 82 1.21
25 108 0.78
35 135 0.554

Any questions for us?

For inquiries about our products or price list , please leave your email to us and we will be in touch within 24 hour