DIN VDE 0276 0.6/1 kV NAYY-J / NAYY-O NAYY Cable AL/PVC/PVC

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

NAYY-J / NAYY-O NAYY cable for power stations, industrial installations and switchgear, and local power supplies.
For fixed installations underground, in indoor locations, in cable ducts, in open air, in water (permitted by local building regulations), if required to protect against electric shock hazards in the event of mechanical damage or electrical shielding.
Concentric countersunk conductors can be used as PE or PEN conductors without cutting when assembling branch splices.

Meaning of Abbreviations

NA= Aluminium conductor
Y= PVC insulation
Y= PVC sheath
O = No earth
J = Green/yellow earth

Conductor abbreviations "re", "rm", "se", "sm":
r = round conductor form;
s = sectorial conductor form;
e = single-wire conductor;
m = multi-wire conductor;

Performance

Voltage Rating:
Uo/U (Um) 0.6/1 (1.2)kV

Test Voltage:
4kV

Temperature Rating:
Fixed installation: -40℃ to +70℃,During installation: -5℃ to +50℃

Maximum Short Circuit Temperature:
+250°C (max 5 seconds)

Minimum Bend Radius:
Single core: 15 x overall diameter
Multi core: 12 x overall diameter

Fire Performance:
Flame-retardant according IEC 60332-1-2

Construction

Conductor:
RE: Class 1 solid aluminium-circular or circular compacted
RM: Class 2 stranded
SM: Class 2 sector - shaped
SE: Class 1 solid sector - shaped or stranded (available upon request)

Insulation:
PVC (Polyvinyl Chloride)

Bedding:
PVC (Polyvinyl Chloride)

Sheath:
PVC (Polyvinyl Chloride)

Core Identification
3 core: Green/Yellow Blue Brown
4 core: Green/Yellow Brown Black Grey
5 core: Green/Yellow Blue Brown Black Grey
7 core and above: Black with White numbers

Sheath Colour:
Black

NAYY NAYY-J NAYY-O (2)

1.Aluminium Conductor
2.PVC Insulation

3.PVC Bedding
4.PVC Sheath

Cable Marking and Packing Materials

Cable Marking:
printing, embossing, engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Specifications

VDE 0276-603, VDE 0276-627, HD 603 S1, HD 627 S1, IEC 60502-1

DIN VDE 0276 0.6/1 kV NAYY-J / NAYY-O NAYY Cable AL/PVC/PVC

no. of cores
x nom. cross
section
max.
conductor
resistance
current
rating
in the ground
current
rating
in the air
outer
diameter
AL-
number
total
weight
mm² Ohm/km A A appr. mm appr. kg/km appr.kg/km
1 × 25 RM 1.2 160 110 12.6 73 210
1 × 35 RM 0.868 193 135 13.6 102 260
1 × 50 RM 0.641 230 166 15.3 145 335
1 × 70 RM 0.443 283 210 16.9 203 425
1 × 95 RM 0.32 340 259 19.1 276 540
1 × 120 RM 0.253 389 302 20.6 348 610
1 × 150 RM 0.206 436 345 22.3 435 745
1 × 185 RM 0.164 496 401 24.6 537 925
1 × 240 RM 0.125 578 479 27.5 696 1.205
1 × 300 RM 0.1 656 555 30.6 870 1.44
1 × 400 RM 0.078 756 653 33.2 1.16 1.85
1 × 500 RM 0.061 873 772 37.7 1.45 2.19

0.6/1kV NAYY-J Cable Specifications

no. of cores
x nom. cross
section
max.
conductor
resistance
current
rating
in the ground
current
rating
in the air
outer
diameter
AL-
number
total
weight
mm² Ohm/km A A appr. mm appr. kg/km appr.kg/km
4 × 25 RM 1,200 102 82 26,7 290 1.032
4 × 35 RE 0,868 123 100 27,8 406 1.129
4 × 35 RM 0,868 123 100 29,3 406 1.18
4 × 50 SE 0,641 144 119 31,9 580 1.295
4 × 50 SM 0,641 144 119 34,4 580 1.353
4 × 70 SE 0,443 179 152 36,1 812 1.74
4 × 70 SM 0,443 179 152 38,0 812 1.818
4 × 95 SE 0,320 215 186 40,3 1.102 2.232
4 × 95 SM 0,320 215 186 43,0 1.102 2.331
4 × 120 SE 0,253 245 216 43,5 1.392 2.66
4 × 120 SM 0,253 245 216 46,6 1.392 2.779
4 × 150 SE 0,206 275 246 47,7 1.74 3.112
4 × 150 SM 0,206 275 246 50,4 1.74 3.251
4 × 185 SE 0,164 313 285 52,7 2.146 4.167
4 × 185 SM 0,164 313 285 57,0 2.146 4.353
4 × 240 SE 0,125 364 338 58,2 2.784 5.15
4 × 240 SM 0,125 364 338 63,2 2.784 5.38