GOST 31946 Self-supporting Isolated And Projected SIP cable

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

Self-supporting isolated and projected SIP cable (ABC Cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost. Tano Cable Self-supporting isolated and projected cables are designed to supply 0.6/1kV, 20kV, 35kV aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting. This overhead cable provides reinforced insulation.

SIP Cable abbreviation

S – self-supporting;
I – insulated;
P – wire;
n, ng – does not support combustion.
A – aluminum conductor;
s – self-supporting wire;
XS – insulation made of cross-linked polyethylene;
n – does not support combustion.

The number in the wire marking indicates the type of construction.
SIP-1 – with a non-insulated neutral self-supporting conductor;
SIP-2 – with an insulated neutral self-supporting conductor;
SIP-3 – with protective insulation;
SIP-4 – without neutral self-supporting conductor with light-stabilized polyethylene insulation;
SIP-5 – without neutral self-supporting conductor, insulated with silanol-crosslinked light-stabilized polyethylene.

Performance

1. Electrical performance:
0.6/1kV,20kV,35kV

2. Chemical performance:
chemical,UV&oil resistance

3. Mechanical performance:
Minimum bending radius:18 x cable diameter

4. Terminal performance:
Maximum service temperature:90℃
Maximum short-circuit temperature: 250℃(Max.5s)
Minimum service temperature:-40℃

Constructions

Conducting Core :
Al Round Core  For All Cross-Section The Core Is Compacted Multiwire, The Quantity Of Wire In Phase Core.

Phase Core Identification:
colour strip, rib or number

Neutral Messenger Core :
Form Al Alloy, Round Core, Stranded From Round Wires, Compacted. 

Insulation:
Sip-1 The Neutral Core Is Not Insulated.Other Conductor Light-Stabilized Cross-Linked PE

GOST 31946 Self-supporting Isolated And Projected SIP cable (2)

Cable Marking and Packing Materials

Cable Marking:
printing, embossing ,engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Specifications

GOST 31946 GOST 15150 standard

SIP-3, SIPn-3, AAsXS, AAsXSn Parameters

20KV
Number of conductors and nominal cross-section Nominal outer diameter Estimated weight of 1 km of wire
mm2 mm kg
1х35 11,7 168
1х50 12,9 210
1х70 14,4 277
1х95 16,3 367
1х120 17,7 446
1х150 19,0 520
1х185 20,9 649
1х240 22,9 798
35kv
Number of conductors and nominal cross-section Nominal outer diameter Estimated weight of 1 km of wire
mm2 mm kg
1х35 14,1 219
1х50 15,3 266
1х70 16,8 339
1х95 18,7 437
1х120 20,1 522
1х150 21,4 600
1х185 23,3 737
1х240 25,3 894

SIP-1 SIPn-1 0.6/1 kv

Number of conductors and nominal cross-section Nominal outer diameter Weight of 1 km of wire
mm2 mm kg
1 x 16 + 1 x 25 13,4 136
3 x 16 + 1 x 25 17,8 274
3 x 25 + 1 x 35 20,8 392
3 x 35 + 1 x 50 23,4 517
3 x 50 + 1 x 50 26,0 654
3 x 50 + 1 x 70 27,1 710
3 x 70 + 1 x 70 30,8 931
3 x 70 + 1 x 95 32,1 1002
3 x 95 + 1 x 70 33,7 1174
3 x 95 + 1 x 95 34,9 1246
3 x 120 + 1 x 95 38,2 1470
3 x 150 + 1 x 95 40,5 1697
3 x 185 + 1 x 95 45,0 2065
3 x 240 + 1 x 95 50,1 2521

SIP-2 SIPn-2 0.6/1 kv

Number of conductors and nominal cross-section Nominal outer diameter Weight of 1 km of wire
mm2 mm kg
3 x 16 + 1 x 25 20,6 306
3 x 25 + 1 x 35 21,8 428
3 x 25 + 1 x 54,6 23,2 489
3 x 35 + 1 x 50 24,6 566
3 x 35 + 1 x 54,6 25,0 581
3 x 50 + 1 x 50 27,1 703
3 x 50 + 1 x 54,6 27,7 718
3 x 50 + 1 x 70 28,6 777
3 x 70 + 1 x 54,6 32,1 939
3 x 70 + 1 x 70 32,1 997
3 x 70 + 1 x 95 33,5 1078
3 x 95 + 1 x 70 36,4 1241
3 x 95 + 1 x 95 36,4 1322
3 x 120 + 1 x 95 39,8 1546
3 x 150 + 1 x 95 43,8 1773
3 x 185 + 1 x 95 46,7 2141
3 x 240 + 1 x 95 50,1 2598

SIPn-4, SIP-5, SIP-5ng, AsXS, AsXSn 0.6/1KV

Number of conductors and nominal cross-section Nominal outer diameter Weight of 1 km of wire
mm2 mm kg
1 x 10 6,2 47
1 x 16 7,4 68
1 x 25 8,6 98
1 x 35 9,7 129
1 x 50 11,3 174
1 x 70 13,3 246
1 x 95 15,1 327
1 x 120 16,5 401
1 x 150 18,2 475
1 x 185 20,2 596
1 x 240 22,5 747
2 x 10 12,4 94
2 x 16 14,8 138
2 x 25 17,2 199
2 x 35 19,4 260
2 x 50 22,5 351
2 x 70 26,6 499
2 x 95 30,2 661
2 x 120 33,1 811
2 x 150 36,3 962
2 x 185 40,4 1207
2 x 240 44,9 1512
3 x 10 13,4 142
3 x 16 15,9 207
3 x 25 18,5 298
3 x 35 20,8 391
3 x 50 24,2 527
3 x 70 28,6 748
3 x 95 32,4 991
3 x 120 35,5 1216
3 x 150 39,0 1443
3 x 185 43,4 1811
3 x 240 48,3 2267
4 x 10 15,0 189
4 x 16 17,8 276
4 x 25 20,8 397
4 x 35 23,4 521
4 x 50 27,1 703
4 x 70 32,1 997
4 x 95 36,4 1322
4 x 120 39,8 1621
4 x 150 43,8 1924
4 x 185 48,7 2415
4 x 240 54,2 3023

Any questions for us?