BS 6622 3.8/6.6kV Aluminium AWA/SWA PVC Armoured Cable

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

AWA/SWA cable means aluminium wire armoured and steel wire armoured cable. Chialawn 3.8/6.6kV AWA/SWA PVC Armoured Cable is used for external and direct burial applications in power networks.

Performance

Electrical performance U0/U:
3.8/6.6 (7.2) kV

Test Voltage (AC):
12.5kV

Mechanical performance:
minimum bending radius:
Single core: 15x overall diameter
Multi core: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bends are positioned adjacent to a joint or termination provided that the bending is carefully controlled by the use of a former)

Terminal performance:
-Maximum service temperature:90℃
-Maximum short-circuit temperature: 250℃(Max.5s)
-Minimum service temperature:-10℃

Fire performance:
-Flame Retardant according to IEC/EN 60332-1-2

Constructions

Conductor:
class 2 stranded compacted aluminium conductor

Insulation:
Semi-conductive XLPE (Cross-Linked Polyethylene)

Insulation Screen:
Semi-conductive XLPE (Cross-Linked Polyethylene)

Metallic Screen:
Concentric copper wires and copper tape

Separator:
Binding tape

Inner Sheath:
PVC (Polyvinyl Chloride)

Armour:
Single core: AWA (Aluminium Wire)
Multi core: SWA (Galvanised steel wire)

Sheath:
PVC (Polyvinyl Chloride)

Sheath Colour:
Red

BS 6622 3.86.6kV Aluminium AWASWA PVC Armoured Cable (2)

1. Conductor
2. Conductor Screen
3. Insulation
4. Insulation Screen

5. Metallic Screen
6. Armour
7. Outer Sheath

Cable Marking and Packing Materials

Cable Marking:
printing, embossing ,engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Specifications

- BS 6622, IEC 60502-2, IEC/EN 60228, HD 620 Standard

3.8/6.6kV Aluminium AWA/SWA PVC Armoured Cable Size Chart Physical Performance

NO. OF  CORES NOMINAL CROSS SECTIONAL AREA NOMINAL OVERALL DIAMETER NOMINAL  WEIGHT
- mm2 mm kg/km
1 35 24.4 823
1 50 25.6 894
1 70 27.7 1.034
1 95 29.6 1.179
1 120 30.8 1.285
1 150 32.5 1.508
1 185 35.2 1.773
1 240 37.9 2.038
1 300 40.8 2.357
1 400 45 2.893
1 500 49.8 3.553
1 630 56.2 4.614
3 50 49 3750
3 70 54 4500
3 95 57 5000
3 120 60 5500
3 150 64 6000
3 185 68 6750
3 240 76 8750
3 300 82 10000
3 400 90 12000
3 500 97 14000

Electrical Performance(Current Carrying Capacity of copper conductor )

NO. OF CORES NOMINAL  CROSS  SECTIONAL  AREA MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C OPERATING INDUCTANCE OPERATING  CAPACITY CONTINUOUS CURRENT RATING
In Ground at 20OC In Air at 30OC
Flat Trefoil Flat Trefoil Flat Trefoil
mm2 ohms/km mH/km mH/km uF/km Amps Amps Amps Amps
1 50 0.641 0.719 0.381 0.297 186 178 233 188
1 70 0.443 0.684 0.357 0.339 234 217 280 235
1 95 0.32 0.659 0.342 0.381 287 259 344 286
1 120 0.253 0.636 0.327 0.416 338 298 392 329
1 150 0.206 0.62 0.319 0.454 388 333 441 376
1 185 0.164 0.602 0.31 0.495 449 377 510 428
1 240 0.125 0.579 0.3 0.556 530 438 587 508
1 300 0.1 0.562 0.295 0.617 605 495 682 586
1 400 0.0788 0.543 0.29 0.681 678 562 781 676
1 500 0.0605 0.525 0.283 0.758 762 633 883 772
1 630 0.0469 0.507 0.276 0.853 858 712 1007 882

 

NO. OF  CORES NOMINAL CROSS SECTIONAL AREA MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C OPERATING  INDUCTANCE OPERATING CAPACITY CONTINUOUS CURRENT RATING
In Ground at 20OC In Air at 30OC
- mm2 ohms/km mH/km uF/km Amps Amps
3 50 0.641 0.33 0.31 162 160
3 70 0.443 0.31 0.37 199 199
3 95 0.32 0.3 0.41 238 242
3 120 0.253 0.29 0.44 271 280
3 150 0.206 0.28 0.49 304 318
3 185 0.164 0.27 0.53 345 365
3 240 0.125 0.27 0.57 401 431
3 300 0.1 0.26 0.58 516 649
3 400 0.0778 0.26 0.61 572 737
3 500 0.0605 0.25 0.65 638 835

Any questions for us?

For inquiries about our products or price list , please leave your email to us and we will be in touch within 24 hour