IEC 60502-1 0.6/1kV XLPE Insulated PVC Armoured Cables

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

These XLPE Insulated PVC Armoured Cables are used indoors or outdoors, in cable furrows, pipes, or tunnels. They are buried underground and can be used to wells, water interiors, and soil with poor drainage.

Performance

Electrical performance U0/U:
0.6/1kV

Chemical performance:
chemical, UV&oil resistance

Mechanical performance:
minimum bending radius:15 x overall diameter

Terminal performance:
-Maximum service temperature:70℃
-Maximum short-circuit temperature: 250℃(Max.5s)
-Minimum service temperature:0℃

Fire performance:
IEC 60332-3-22, IEC 60332-3-23, and IEC 60332-3-24 standard-compliant flame retardant
Halogen-free materials must adhere to IEC 60754-1/2 and IEC 60684-2 standards.

Construction

Conductors:
Round or shaped conductors made of copper or aluminum, class 2 according to IEC 60228

Insulation:
XLPE Insulation material

Assembly / Inner Sheath:
2.3.4 core non-hygroscopic filler,PVC Bedding.

Armour:
Single core:AWA; Multi-core:SWA/STA

Core Identification
One Color:red or black
Two cores:red, black
Three cores:red,yellow and blue
Four cores:red,yellow,blue and black
Five cores:red,yellow,blue,black and green/yellow
Above Five Cores:Black Cores with White numerals

Outer Sheath:
PVC(Polyvinyl chloride)

IEC 60502-1 0.61kV XLPE Insulated PVC Armoured Cables ( (3)

Cable Marking and Packing Materials

Cable Marking:
printing, embossing, engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Specifications

IEC 60502-1 Standard

IEC 60502-1 0.6/1kV CU XLPE AWA PVC Cable Single Core Data Sheet

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Alum Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm2 mm mm mm mm mm mm
1×4 2.3 0.7 1 0.8 1.8 10.9
1×6 2.8 0.7 1 0.8 1.8 11.4
1×10 3.6 0.7 1 0.8 1.8 12.2
1×16 4.5 0.7 1 0.8 1.8 13.1
1×25 5.6 0.9 1 0.8 1.8 14.6
1×35 6.7 0.9 1 1.25 1.8 16.6
1×50 8 1 1 1.25 1.8 18.1
1×70 9.4 1.1 1 1.25 1.8 19.7
1×95 11 1.1 1 1.6 1.8 22
1×120 12.4 1.2 1 1.6 1.8 23.6
1×150 13.8 1.4 1 1.6 1.8 25.4
1×185 15.3 1.6 1 1.6 1.8 27.4
1×240 17.5 1.7 1 1.6 1.9 29.9
1×300 19.5 1.8 1 2 2 33.1
1×400 22.6 2 1.2 2 2.2 37.3
1×500 25.2 2.2 1.2 2 2.3 40.5

IEC 60502-1 0.6/1kV CU XLPE PVC SWA PVC Cable Two Core Data Sheet

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm2 mm mm mm mm mm mm
2×1.5 1.4 0.7 1 0.8 1.8 12.8
2×2.5 1.8 0.7 1 0.8 1.8 13.6
2×4 2.3 0.7 1 0.8 1.8 14.6
2×6 2.8 0.7 1 1.25 1.8 16.5
2×10 3.6 0.7 1 1.25 1.8 18.1
2×16 4.5 0.7 1 1.25 1.8 19.9
2×25 5.6 0.9 1 1.6 1.8 23.6
2×35 6.7 0.9 1 1.6 1.8 25.8
2×50 8 1 1 1.6 1.9 29
2×70 9.4 1.1 1 2 2 33.2
2×95 11 1.1 1.2 2 2.1 37.1
2×120 12.4 1.2 1.2 2 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 2.6 49.9
2×240 17.5 1.7 1.4 2.5 2.7 55.1
2×300 19.5 1.8 1.6 2.5 2.9 60.2
2×400 22.6 2 1.6 2.5 3.1 67.7

IEC 60502-1 0.6/1kV Three Core Copper Cable XLPE SWA PVC Data Sheet

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm2 mm mm mm mm mm mm
3×1.5 1.4 0.7 1 0.8 1.8 13.2
3×2.5 1.8 0.7 1 0.8 1.8 14.1
3×4 2.3 0.7 1 0.8 1.8 15.2
3×6 2.8 0.7 1 1.25 1.8 17.1
3×10 3.6 0.7 1 1.25 1.8 18.9
3×16 4.5 0.7 1 1.25 1.8 20.8
3×25 5.6 0.9 1 1.6 1.8 24.7
3×35 6.7 0.9 1 1.6 1.8 27.2
3×50 8 1 1 1.6 1.9 30.6
3×70 9.4 1.1 1 2 2.1 35.2
3×95 11 1.1 1.2 2 2.2 39.3
3×120 12.4 1.2 1.2 2 2.3 43
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3 64
3×400 22.6 2 1.6 3.15 3.3 73.5

IEC 60502-1 0.6/1kV CU Steel Wire Armoured XLPE Cable 3.5 Core Data Sheet

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm2 (3) mm (1) mm (3) mm (1) mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8
3×400/185 22.6 15.3 2 1.6 1.6 3.15 3.6 78.6

IEC 60502-1 0.6/1kV 4 C XLPE SWA PVC CU Cable Data Sheet

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm2 mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3