IEC 60502-1 Standard XLPE Insulated Steel Wire Armoured Control Cable & Auxiliary Cable

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

XLPE Insulated Steel Wire Armoured Control Cable is designed to facilitate land-based activities in the oil,gas,petroleum and chemical industries where the spillage or seepage of corrosive liquids and vapours pose a threat to circuit integrity.
Contaminants such as petroleum-based substances are capable of permeating cable sheath and passing along and between armour wires,thus the inevitable degradation of insulating materials may not be limited to the proximity of penetration.

Performance

Voltage rating U0/U(Um):
600/1000V

Chemical performance:
chemical, UV&oil resistance

Thermal performance:
-Maximum operating temperature:90℃
-Maximum short-circuit temperature: 250℃(Max.5s)
-Minimum service temperature:-10℃

Fire performance:
-Flame retardant according to IEC/EN 60332-1-2 standard
-Reduced emission of halogens chlorine <15%

Construction

Conductor:
plain copper conductor

Insulation:
XLPE (cross-linked polyethylene)
-alternative:PVC(Polyvinyl chloride)

Filler:
non-hygroscopic polypropylene
Binding Tape:

polyester tape or non-woven fabric

Inner Sheath:
PVC(Polyvinyl chloride)
-alternative: LSZH (Low Smoke Zero Halogen)

Optional Lead Sheath:
Lead alloy

Armour (multi core):
galvanized steel wires for all multi-core cables

Outer Sheath:
PVC (polyvinyl chloride)
-alternative :LDPE, MDPE (Low/Medium Density Polyethylene)
-alternative: LSZH (Low Smoke Zero Halogen)

Core Identification:
Single Core:Red or Black
Two Cores: Red,Black
Three Cores:Red,Yellow,Blue
Four Cores:Red,Yellow,Blue,Black
Five Cores:Red,Yellow,Blue,Black,Green/Yellow
Five or More: White cores with number printing in black

IEC-60502-1-Standard-Control-Cable-(2)

1. Stranded Copper Conductor
2. Cross-linked polyethylene insulated
3. Polyvinyl Chloride Filler

4. Galvanised Round Steel Wire Armour
5. Polyvinyl Chloride Outer Sheath

Cable Marking and Packing Materials

Cable Marking:
printing, embossing, engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Standards

- IEC 60502-1, IEC/EN 60228

IEC 60502-1 Standard XLPE Insulated Steel Wire Armoured Control Cable & Auxiliary Cable Physical Performance and Resistance

No.of Cores

Nominal Section Area

Min. Number of Individual Wires in Conductor

Nominal Thickness of Insulation

Diameter of Armour Wire

Maximum D.C. Resistance of Conductor at 20℃

Circular

Circular Compact

Sectorial

Cu

Al

Cu

Al

Cu

Al

Cu

Al

-

mm2

-

-

-

-

-

-

mm

mm

Ω/km

Ω/km

2,3,4,5

1.5

7

-

6

-

-

-

0.7

0.9

12.1

-

2,3,4,5

2.5

7

-

6

-

-

-

0.7

1.25

7.41

-

2,3,4,5

4

7

-

6

-

-

-

0.7

1.25

4.61

-

2,3,4,5

6

7

-

6

-

-

-

0.7

1.25

3.08

-

2,3,4,5

10

7

7

6

6

-

-

0.7

1.25

1.83

-

2,3,4,5

16

7

7

6

6

-

-

0.7

1.6

1.15

1.91

2,3,4,5

25

7

7

6

6

6

6

0.9

1.6

0.727

1.20

2,3,4,5

35

7

7

6

6

6

6

0.9

1.6

0.524

0.868

2,3,4,5

50

19

19

6

6

6

6

1.0

2.0

0.387

0.641

2,3,4

70

19

19

12

12

12

12

1.1

2.0

0.268

0.443

2,3,4

95

19

19

15

15

15

15

1.1

2.5

0.193

0.320

2,3,4

120

37

37

18

15

18

15

1.2

2.5

0.153

0.253

2,3,4

150

37

37

18

15

18

15

1.4

2.5

0.124

0.206

3,4

185

37

37

30

30

30

30

1.6

2.5

0.0991

0.164

3,4

240

37

37

34

30

34

30

1.7

2.5

0.0754

0.125

3,4

300

61

61

34

30

34

30

1.8

3.15

0.0601

0.100

3,4

400

61

61

53

53

53

53

2.0

3.15

0.0470

0.0778

7,10,12,19,24,27,37,48

1.5

7

-

6

-

-

-

7,10,12,19,24,27,37,48

2.5

7

-

6

-

-

-

7,12,19,27,37,48

4

7

-

6

-

-

-

Electrical Performance Current Carrying Capacity (copper conductor )

Nominal Cross Sectional Area

Reference Method C

(Clipped Direct)

Reference Method E

(in Free Air or on A Perforated Cable Tray Horizontal or Vertical)

Reference Method D

 (Direct in Ground or in Ducting Ground in or Around Buildings)

1 two core cable single-phase         A.C. or D.C.

1 there or 1 four core cable three-phase A.C.

1 two core cable single-phase         A.C. or D.C.

1 three or 1 four core cable three-phase A.C.

1 two core cable single-phase         A.C. or D.C.

1 three or 1 four core cable three-phase A.C.

mm ²

amp

amp

amp

amp

amp

amp

1.5

27

23

29

25

25

21

2.5

36

31

39

33

33

28

4

49

42

52

44

43

36

6

62

53

66

56

53

44

10

85

73

90

78

71

58

16

110

94

115

99

91

75

25

146

124

152

131

116

96

35

180

154

188

162

139

115

50

219

187

228

197

164

135

70

279

238

291

251

203

167

95

338

289

354

304

239

197

120

392

335

410

353

271

223

150

451

386

472

406

306

251

185

515

441

539

463

343

281

240

607

520

636

546

395

324

300

698

599

732

628

446

364

400

787

673

847

728

-

570

Note
Air ambient temperature: 30℃
Ground ambient temperature: 0℃
Conductor operating temperature: 90℃

Any questions for us?

For inquiries about our products or price list , please leave your email to us and we will be in touch within 24 hour