ASTM 35kV Medium Voltage Covered Conductors AAAC 3-layer Track-resistant PE

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

In addition to spacer cables, tree wires or tree-friendly wires are used in areas with heavy vegetation growth or where trees are located near power lines.
Tree wires consist of a central bare conductor surrounded by insulation and an outer conductor with a series of AAAC conductor. The outer conductor is designed to bend and move with the branches without harming the tree or causing damage to the power cord. Increased installation clearance for tree wires helps prevent trees from touching power lines and causing power outages. They are often used in residential and urban areas where trees are common.

Constructions

All-aluminum alloy conductor in a single cable with a 2-layer covering, a 3-layer extruded shield, and a shield made of semiconducting thermoplastic conductor that has been extruded.
LDPE, MDPE, or HDPE makes up the covering inner layer, while track-resistant medium- or high-density polyethylene (TK-MDPE or TK-HDPE) makes up the outer layer.
Each layer is joined by a bond.

Conductor:
AAC (1350-H19, compact stranded).

Conductor Shield:
Extruded semiconducting thermoplastic shield which is free stripping from the conductor and bonded to the covering.

Inner and Outer Covering:
2-layer LDPE, MDPE or HDPE, where the outer layer is track-resistant (TK-MDPE or TK-HDPE).

ASTM 35kV Medium Voltage Covered Conductors AAAC 3-layer Track-resistant PE (2)

Standards

These cables are manufactured and tested to meet or exceed the following standards:
ASTM B230 – Aluminum 1350–H19 Wire for Electrical Purposes
ASTM B231 – Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B400 – Compact Round Concentric-Lay-Stranded Conductors
ASTM D1248 – Polyethylene Plastics Extrusion Materials for Wire and Cable
ICEA S-121-733 – Tree Wire and Messenger Supported Spacer Cable 

ASTM Standard 35kV Aerial Overhead Electrical Wire AAAC PE

Conductor
Size
Equivalent
AAC
Conductor
Stranding
Conductor
Diameter
Conductor
Shield
Thickness
Covering
Thickness
Inner
Layer
Covering
Thickness
Outer
Layer
Overall
Diameter
Weight
Conductor
Weight
Net
Rated
Strength
AWG
or
kcmil
AWG
or
kcmil
No. in in in in in lb/FT lb/FT lb/FT
48.69 4 7 0.25 0.015 0.175 0.125 0.88 45.4 290 1760
77.47 2 7 0.316 0.015 0.175 0.125 0.946 72.24 345 2800
123.3 1/0 7 0.398 0.015 0.175 0.125 1.028 114.9 423 4270
155.4 2/0 7 0.447 0.015 0.175 0.125 1.077 144.9 474 5390
195.7 3/0 7 0.502 0.015 0.175 0.125 1.132 182.5 536 6790
246.9 4/0 7 0.563 0.015 0.175 0.125 1.193 230.2 610 8560
312.8 266.8 19 0.642 0.015 0.175 0.125 1.272 291.6 705 10500
394.5 336.4 19 0.721 0.015 0.175 0.125 1.351 367.9 816 13300
465.4 397.5 19 0.783 0.015 0.175 0.125 1.413 433.9 909 15600
559.5 477 19 0.858 0.02 0.175 0.125 1.498 521.7 1039 18800
652.4 556.5 19 0.927 0.02 0.175 0.125 1.567 608.3 1156 21900

Any questions for us?