ASTM B800 B836 600V or 1000V XLPE PVC XHHW 2 Wire

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

XLPE PVC 2 XHHW Aluminum Wire is suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired.
These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TCER) per NEC 336.10. Silicone free.

Construction

Conductor:
Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836

Or Compact bare AA-8000 series aluminum alloy, Class B stranded per ASTM

Insulation:
Cross Linked Polyethylene (XLPE) Type XHHW-2

Grounding Conductor:
Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836

Filler:
Paper filler (cable size 8 & 6 uses Polypropylene filler)

Binder:
Polyester flat thread binder tape for cable sizes larger than 2 AWG

Overall Jacket:
Polyvinyl Chloride (PVC) Jacket

ASTM-B800-B836-600V-or-1000V-XLPE-XHHW-2-PVC-Power-Cable-(2)

1. Conductor:7 strands class B compressed copper per ASTM B3 and ASTM B8
2. Insulation:Cross Linked Polyethylene (XLPE) XHHW-2
3. Filler:Polypropylene filler / Paper filler
4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
5. Overall Jacket:Thermoplastic Chlorinated Polyethylene Jacket

Cable Marking and Packing Materials

Cable Marking:
printing, embossing, engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Specifications

• ASTM B800 8000 Series Aluminum Alloy Wire
• ASTM B836 Compact Rounded Stranded Aluminum Conductors
• UL 44 Thermoset-Insulated Wires and Cables
• UL 1277 Electrical Power and Control Tray Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)

ASTM B800 B836 600V or 1000V XLPE PVC 2 XHHW aluminum wire Specification

Physical Performance
Cond.  Size Diameter Over Conductor Insul.  Thickness Diameter Over Insulation Ground Jacket  Thickness Approx.  OD Aluminum  Weight Approx.  Weight
AWG/  Kcmil inch mil inch No. x AWG mil inch lb/1000ft lb/1000ft
8 0.134 45 1×8 60 0.604 63 180

Electrical Performance

Cond.  Size Min Bending Radius Max Pull Tension DC Resistance @ 25°C AC Resistance @ 90°C Inductive Reactance @ 60Hz Shield Short Circuit Current 6 Cycles Allowable Ampacity At 60°Ct Allowable Ampacity At 75°Ct Allowable Ampacity At 90°Ct
AWG/  Kcmil inch lb Ω/1000ft Ω/1000ft Ω/1000ft Amp Amp Amp Amp
8 2.4 297 1.07 1.345 0.034 3785 35 40 45

Any questions for us?

For inquiries about our products or price list , please leave your email to us and we will be in touch within 24 hour