SANS 1418 SANS 1713 MV ABC Wire And Cable

DOWNLOAD CATEGORY SPECIFICATIONS

Product Details

Product parameter

Application

MV ABC Wire And Cable is the most effective for power grid transformation in urban, forest, and coastal areas. It also works great for overhead power transmission. The system is more efficient, reliable, and economical. These types of cables have the ability to bare voltage levels of 10kv and below, 3.8/6.6kV, 6.35/11kV, 12.7/22kV , 19/33kV, etc. The ABC conductor used is aluminum and has a circular shape. The insulation material mostly used is XPLE. The material used for inner and outer semiconductor is compound, but the bedding material is semi-conducting. The screen comprises a copper tape or a copper wire. Moreover, the outer sheath is HDPE.
This type of ABC Cable is suitable for For use in power circuits of earthed systems , Suspended in air .

Performance

1. Electrical performance:
3.8/6.6kV, 6.35/11kV, 12.7/22kV , 19/33kV

2. Chemical performance:
chemical, UV&oil resistance

3. Mechanical performance:
Minimum bending radius:10 x cable diameter

Construction

Conductor:
circular Aluminium stranded conductor

Phase Core Identification:
colour strip, rib or number

Core:
3 Core

Insulated:
XLPE insulated

Screened:
individually Copper tape screened

Sheathed:
flame retardant PVC, flame retardant PVC sheathed + steel catenary

SANS 1418 SANS 1713 MV ABC Wire And Cable (2)

Cable Marking and Packing Materials

Cable Marking:
printing, embossing ,engraving

Packing Materials:
wooden drum, steel drum, steel-wooden drum

Standard

SANS 1418 SANS 1713 Standard ABC Wire

SANS 1418 SANS 1713 MV Aerial Bundled Cable

6.6kV ABC Cable Specification
Phase Core
Conductor size mm2 nom 35 50 70 95 120 150 185
Conductor diameter mm app. 7.15 8.25 9.95 11.8 13.1 14.8 15.95
Insulation diameter mm app. 15.4 16.5 18.2 20.1 21.4 22.7 24.2
Core sheath diameter mm app. 20.5 21.6 23.5 25.5 26.8 28.1 29.9
Catenary (Support Core)
Conductor size mm2 nom 50 50 50 50 70 70 70
Conductor diameter mm app. 9 9 9 9 10.8 10.8 10.8
Insulation diameter mm app. 11.5 11.5 11.5 11.5 13.3 13.3 13.3
Maximum tensile strength and pulling force of catenary kN 26 26 26 26 37 37 37
Cable
Cable diameter mm app. 44 47 51 55 58 61 65
Cable mass kg/m app. 2.05 2.24 2.6 3.01 3.51 3.85 4.33
Gross mass (500m) kg app. 915 973 1,079 1,204 1,354 1,454 1,599
Bending radius mm min. 636 669 720 776 841 880 926
Current rating
In air Amps 150 185 230 280 325 370 430
Resistance
dc @ 20°C W/km max 0.868 0.641 0.443 0.32 0.253 0.206 0.164
ac @ 90°C W /km max 1.113 0.822 0.568 0.411 0.325 0.265 0.211
Reactance W /km 0.136 0.124 0.121 0.114 0.111 0.106 0.103
Impedance W /km 1.121 0.832 0.581 0.426 0.342 0.284 0.233
Short circuit ratings
Symmetrical kA (1 sec) 3 4 5.8 8 10.2 12.5 15.7
Earth fault kA (1 sec) 1.5 1.6 1.7 1.9 2 2.1 2.3
11kv ABC Cable Specification
Phase Core
Conductor size mm2 nom 35 50 70 95 120 150 185
Conductor diameter mm app. 7.15 8.25 9.95 11.8 13.1 14.8 16.35
Insulation diameter mm app. 17.3 18.4 20.1 21.9 23.2 24.5 26.1
Core sheath diameter mm app. 22.5 23.6 25.3 27.4 28.7 30.2 31.7
Catenary (Support Core)
Conductor size mm2 nom 50 50 50 50 70 70 70
Conductor diameter mm app. 9 9 9 9 10.8 10.8 10.8
Insulation diameter mm app. 11.5 11.5 11.5 11.5 13.3 13.3 13.3
Maximum tensile strength and pulling force of catenary kN 26 26 26 26 37 37 37
Cable
Cable diameter mm app. 49 51 55 59 62 65 69
Cable mass kg/m app. 2.31 2.52 2.85 3.28 3.61 3.99 4.43
Gross mass (500m) kg app. 993 1,055 1,155 1,285 1,382 1,496 1,628
Bending radius mm min. 691 724 775 831 896 935 981
Current rating
In air Amps 150 185 230 280 325 370 430
Resistance
dc @ 20°C W/km max 0.868 0.641 0.443 0.32 0.253 0.206 0.164
ac @ 90°C W /km max 1.113 0.822 0.568 0.411 0.325 0.265 0.211
Reactance W /km 0.136 0.124 0.121 0.114 0.111 0.106 0.103
Impedance W /km 1.121 0.832 0.581 0.426 0.342 0.284 0.233
Short circuit ratings
Symmetrical kA (1 sec) 3 4 5.8 8 10.2 12.5 15.7
Earth fault kA (1 sec) 1.5 1.6 1.7 1.9 2 2.1 2.3
22kV ABC Cable Specification
Phase Core
Conductor size mm2 nom 35 50 70 95 120 150 185
Conductor diameter mm app. 7.15 8.25 9.95 11.8 13.1 14.8 16.35
Insulation diameter mm app. 21.6 22.7 24.4 26.2 27.5 29.2 30.8
Core Sheath diameter mm app. 27 28.1 30 31.9 33.4 35.1 36.8
Catenary (Support Core)
Conductor size mm2 nom 50 50 50 50 70 70 70
Conductor diameter mm app. 9 9 9 9 10.8 10.8 10.8
Insulation diameter mm app. 11.5 11.5 11.5 11.5 13.3 13.3 13.3
Maximum Tensile Strength and Pulling force of Catenary kN 26 26 26 26 37 37 37
Cable
Cable diameter mm app. 58 61 65 69 72 76 80
Cable mass kg/m app. 2.96 3.19 3.61 4.05 4.63 5.06 5.61
Gross mass (500m) kg app. 1 188 1 257 1 383 1 514 1 690 1 819 1 984
Bending radius mm min. 821 854 905 960 1025 1076 1123
Current rating
In air Amps 150 185 230 280 325 370 430
Resistance
dc @ 20°C W/km max 0.868 0.641 0.443 0.32 0.253 0.206 0.164
ac @ 90°C W /km max 1.113 0.822 0.568 0.411 0.325 0.265 0.211
Reactance W /km 0.136 0.124 0.121 0.114 0.111 0.106 0.103
Impedance W /km 1.121 0.832 0.581 0.426 0.342 0.284 0.233
Short circuit ratings
Symmetrical kA (1sec) 3 4 5.8 8 10.2 12.5 15.7
Earth fault kA (1sec) 1.5 1.6 1.7 1.9 2 2.1 2.3
33kV ABC Cable Specification
Phase Core
Conductor size mm2 nom 50 70 95 120 150 185
Conductor diameter mm app. 8.25 9.95 11.8 13.1 14.8 16.35
Insulation diameter mm app. 27.8 29.5 314 32.7 34 35.5
Core Sheath diameter mm app. 33.7 35.4 37.4 38.7 40.2 41.8
Catenary (Support Core)
Conductor size mm2 nom 50 50 50 70 70 70
Conductor diameter mm app. 9 9 9 10.8 |10.80 10.8
Insulation diameter mm app. 11.5 11.5 11.5 13.3 13.3 13.3
Maximum Tensile Strength and Pulling force of Catenary kN 26 26 26 37 37 37
Cable
Cable diameter mm app. 73 76 81 84 87 90
Cable mass kg/m app. 4.12 4.53 5.06 5.37 5.82 6.33
Gross mass (500m) kg app. 1,535 1,658 1,819 1,910 2,046 2,200
Bending radius mm min. 1007 1058 1114 1179 |1218 1264
Current rating
In air Amps 185 230 280 325 370 430
Resistance
dc @ 20°C W/km max 0.641 0.443 0.32 0.253 0.206 0.164
ac @ 90°C W/km max 0.822 0.568 0.411 0.325 0.265 0.211
Reactance W /km 0.124 0.121 0.114 0.111 0.106 0.103
Impedance W /km 0.832 0.581 0.426 0.342 0.284 0.233
Short circuit ratings
Symmetrical kA (1 sec) 4 5.8 8 10.2 12.5 15.7
Earth fault kA (1 sec) 1.6 1.7 1.9 2 2.1 2.3