IEC 60502-1 IEC60227 IEC 60228 XLPE Control Cable 450/750V

CATEGORY DOWNLOAD SPECIFICATIONS

Product Details

Product parametri

Applicationem

XLPE Control Cable ad refrenandum electrica apparatu et instrumenti metra, vigilantia et moderatio reditus ambitus, tuendi ac mensurandi in distributionibus potentiae cum voltage aestimatis usque ad 450/750V(0.6/1KV) AC

Euismod

U0 electrica perficientur:
450/750V

Operatio chemica:
chemica, UV&olei resistentia

Mechanica perficiendi:
Minimum inflexio radiorum: x10 cable diameter

Terminatio perficientur:
Maximum ministerium temperatus: 90℃
Maximum breve spatium temperatus: 250°C (max. 5s) Minimum ministerium temperatus: -40°

Ignis effectus;
Flamma non propagationis basis in lEC 60332-1Standard

Construction

XLPE insulatas funibus imperium

exemplar

nomen

application

KYJV XLPE insulatas PVC vaginantes funem imperium Ad domesticas, funem fossam, pipelinum et alia loca fixa
KYJYP XLPE insulatas Ad domesticas, funem fossam, pipelinum et alia requisita ad scuta iacienda
KYJVP2 XLPE insulatas PVC vaginatus aeris protectus funem imperium Ad domesticas, funem fossam, pipelinum et alia requisita ad scuta iacienda
KYJVP3 XLPE insulatas PVC aluminium vaginatum aluminium compositum taenia clypeus imperium cables Ad domesticas, funem fossam, pipelinum et alia requisita ad scuta iacienda
KYJV22 XLPE insulatas PVC vaginantes funem imperium Ad domesticas, funem fossam, pipelinum, sepulturam dirigunt maiorem vim mechanicam figentes institutionem sustinentes
KYJVP2-22 XLPE insulatas PVC taenia aenea clypeus vaginatus taenia clypeus armatus funestus imperium Ad domesticas, funem fossam, pipelinum, sepulturam dirigunt maiorem vim mechanicam figentes institutionem sustinentes
KYJV32 XLPE insulatas PVC vaginatas filum ferreum armatae funis imperium Apta aquae vel altae guttae area, externas copias mechanicas et magnas tensiones ferre potest
KYJVR XLPE insulatas PVC vaginantes funem imperium Ad domesticas struendas, mobiles & flexibiles
KYJVRP XLPE insulatas Ad domesticas iaciendas, scutum mobile et flexibile
NOTE:
Haec series' nucleus funis commendatur pro: 2、3、4、5、7、8、10、12、14、16、19、24、27、30、37、44、48、52、61.
IEC-60502-1-IEC60227-IEC-60228-XLPE-Cable-450-750V-(2).

1) conductor
II) Insulation
III) Filler
IV) Tape Seneca

V) velamen
6) Armour
VII) Per Vagina

Cable Vestigium et sarcina Materials

Cable Vestigium:
impressio, impressio, engraving

Materias stipare:
lignea tympanum, chalybe orum, chalybe-ligneus

Signa

IEC 60502-1 IEC60227 IEC 60228, etc.
Alia signa praesto sunt

XLPE MAGISTERIUM MENSURA CHARTA

Nec. Descriptiones Rated voltage Nominal conductor sectione transversali (mm2)
0.75 1 1.5 2.5 4 6 10
U0/U* Numerus metretas
1 Aeris conductor PVC insulatas PVC vaginatas retinacula imperii 450/750V 2~61 2~14 2~10
2 Aeris conductor PVC insulatas et circumtetas funem flexibile imperium 450/750V 2~61 -- --
3 Aeris conductor PVC insulatas et filum aeneum in vaginam plicantes funes scutati potestates 450/750V 4~61 4~14 4~10
4 Aeris conductor PVC insulatas et filum aeneum vaginatum plectentes funestum imperium flexibile 450/750V 2~61 -- --
5 Aeris conductor PVC insulatas PVC vaginatas taenia aenea tuta imperium retinacula 450/750V 4~61 4~14 4~10
6 Aeris conductor PVC Insulated PVC Contectus aeneus Tape armatus taenia armata Imperium cables 450/750V 7-61 4~61 4~14 4~10
7 Aeris conductor PVC insulatas PVC vaginatas chalybeas taenia armatas potestates retinacula 450/750V 7~61 4~61 4~14 4~10
8 Aeris conductor PVC insulatas PVC circumfusa ferro filum armatae potestates retinacula 450/750V 7~61 4~61 4~14 4~10

Quaere nobis?

Percontatione de instrumentis nostris vel pretio indice, electronicam tuam nobis relinque et intra XXIV horas erimus