AEIC CS8 5-35kV Al Conductor AIA cable Aluminium interlocked Armor

CATEGORY DOWNLOAD SPECIFICATIONS

Product Details

Product parametri

Applicationem

Optio parabilis, tenax, et fidelis ad funem intensivum laboris in ductum technicis wiring technicis providetur ab Al Conductor AIA Cable Aluminium Armor interclusum.
in subsidiis inauguratus, qui non plus quam sex pedes distant, ut tormenta metallica, canalia, curricula, funem fercula, uncis.
institutis in humidis vel siccis fundis, opere humido vel sicco, statim in concreto defosso vel infixo, et opere detecto vel occulto.

Construction

Conductor:
A vel B classis ASTM B 231-obnixus compressus aluminii concentrici destitutus mixturae 1350. Cum conductor saturitatem compositam, conductores destitutus aqua- rum obstructus est.

Conductor clypeus:
Insulation-boning thermosetting extructa semiconducting operimentum quod liberum est a conductore decorticare.

Insulatio:
Arbor-Retardant Crucem Polyethylene connexa (TRXLPE), de qua in ANSI/ICEA S-94-649, materia est extrusa, non impleta.

Nulla scutum:
Clypeus thermosetting semiconductus extruditur cum adhaesione moderata ad insaltationem comparatam debitam aequilibrium inter integritatem electricam et facilitatem nudandi.

Scutum metallicum:
Clypeus metallicus planus est uncoated 5-mil crassus taeniola cuprea helice applicata cum minimum 20% overlap.

Humus Wire:
Tria fila aenea nuda humo interstitium conductoris posuerat.

Fillers:
Non fillers hygroscopicus, firmum et cylindricum nucleum formans.

Tape ligans:
Ligans taeniola ad nucleum symmetriam et mechanicam stabilitatem applicatur.

Armor:
Aluminium interlocked armatura super ligans taenia dilabi nucleo applicata

Jacket:
Niger, solis renitens, flamma retardat PVC jacket

AEIC CS8 5-35kV Al Conductor AIA Cable Aluminium Interlocked Armor (2)

1.Conductor
2.Conductor clipeus
3.Insulation
4.Insulation scutum
5.Copper Tape Shied

6.Ground Conductor
7.Filler
8.Binder
9.AIA Armor
10.Overall Jacket

Cable Vestigium et sarcina Materials

Cable Vestigium:
impressio, impressio, sculptura

Materias stipare:
lignea orum, chalybea tympanum, chalybe-ligneus

Specifications

- AEIC CS8, Specificationes pro Shielded Power Cable, 5-46kV
- ICEA S-93-639, 5-46 kV Shielded Power Cable
- ICEA S-97-682, Utilitas Shielded Power Cable Rated 5-46 kV
- UL-1072 MV-105 .

- UL-1569, Metallum Cables
- IEEE 383 Flamma Test
- Pro continuum 105°C, subitis 140°C, operatio brevis 250°C.
- MC-HL praesto ad petitionem

AEIC CS8 5-35kV Al Conductor AIA Cable Specification

Magnitudo Insulation
Crassitudo
Humus
filis
Magnitudo of
Humus
filis
Conductor
Diameter
Insulation
Diameter
Insulation
Scutum
Diameter
Super
Jacket
Diameter
Proxime
Pondus
Minimum
curvus
Radius
Ampacity
105ºC
in
Duct
Ampacity
105ºC
in
Air
AWG / KCMIL (mil) Nec. AWG in in in in lb/MFT in - -
4 90 3 10 0.215 0.45 0.51 1.47 1001 11 86 90
2 90 3 10 0.266 0.5 0.56 1.58 1165 12 110 120
1 90 3 10 0.299 0.53 0.59 1.68 1298 12 130 140
1/0 90 3 10 0.336 0.57 0.63 1.75 1431 13 150 160
2/0 90 3 8 0.379 0.61 0.67 1.87 1698 14 170 185
3/0 90 3 8 0.423 0.66 0.71 1.96 1887 14 195 215
4/0 90 3 8 0.479 0.71 0.77 2.08 2121 15 220 250
250 90 3 8 0.522 0.76 0.82 2.19 2338 16 245 280
350 90 3 7 0.622 0.86 0.92 2.44 2927 18 310 345
500 90 3 6 0.124 0.98 1.05 2.73 3734 20 365 430
750 90 3 5 0.917 1.16 1.24 3.14 4987 23 460 550
1000 90 3 4 1.071 1.32 1.39 3.48 6177 25 535 650

Quaere nobis?