ABNT NBR 11873 Medium Voltage Ecological Cable Al Conductor

CATEGORY DOWNLOAD SPECIFICATIONS

Product Details

Product parametri

Applicationem

Medium Voltagium Ecologicum Cable dicitur funis tensio ecologico media in Spanish, cum typo AAC (Alluminium conductor), ACSR (Aluminium Conductor Ferri confirmatus) cum genere AA et A fila conductor.funis tensionis instrumentorum ecologicorum adhibetur pro transmissione et distributione linearum energiae electricae, in locis silvestribus vel industrialibus.Intentio muneris eius pro omnibus applicationibus secundum crassitudinem parietis insulationis variat et potest esse 15 kV et 25 kV.

Construction

Medium voltagium Ecologicum cables generis AAC, ACSR et concentrically filatae sunt et cum 1350-H19 filis mixturae construuntur.Prima tunica semiconductoris materiae metallicae conductoris applicatur et postea uniformi strato polyethylene connexo insulatur.(XLPE).Forma fasciculi eius in longitudine agit secundum necessitates emptoris.

Euismod

Maximam intentionem operativam: 15KV ad 35KV
Maximum operating temperatus: LXXV °C vel XC °C

Cable Vestigium et sarcina Ratio

Cable Vestigium: impressio, impressio, engraving
Materias stipare:lignea orum, chalybea tympanum, chalybe-ligneus

Standard

• ASTM B230: Aluminium fila, mixtura 1350-H19 ad usus electrica.
• ASTM B400: Standard Specification for Foedus Round Concentrici-Laici destitutum Aluminium 1350 Conductores
• ASTM B231: Typus 1350-H19 conductores in stratis concentricis aluminii subductis.
• ASTM B232: Aluminium Conductor Stranded Ferro confirmatus (ACSR)
• ASTM B232: Aluminium Conductor Stranded Ferro confirmatus (ACSR)
• ICEA S-121-733: Lignum filum et Viator fultum spacer Cable
• ABNT EB-2173: Conductores XLPE obductis polyethylene connexis, ad usum 15 et 25 kV siluestribus locis.
• ABNT/NBR 11873: Cables materia polymerica XLPE obducta pro reticulis aeria distributione compactis in voltages ab 13.8 kV ad 34.5 kV.

CABLE AAC 25 kV

Magnitudo Sectio Area Phase Conductor Conductor Diameter Semiconductor Crassitudo Vagina Crassitudo Cable Diameter Proxime.Totalis Pondus Fractio Load Current Capacitas
No.of Threads Diameter filum
(AWG vel kcmil) (mm2) Nec. (mm) (mm) (mm) (mm) (mm) ( kg / km ) ( kgf ) (A)
2 33.62 7 2.474 7.42 0.7 4.1 17.02 274.46 612 175
1/0 53.49 19 1.892 9.46 0.7 4.1 19.06 357.82 980 235
2/0 67.44 19 2.126 10.63 0.7 4.1 20.23 415.17 1212 270
3/0 85.02 19 2.388 11.94 0.7 4.1 21.54 485.06 1500 310
4/0 107.2 19 2.680 13.4 0.7 4.1 23 570.5 1822 355
266.8 135.2 19 3.010 15.05 0.7 4.1 24.65 675.63 2254 410
336.4 170.5 19 3.381 16.91 0.7 4.1 26.51 796.82 2789 485
477 241.7 37 2.884 20.19 0.7 4.1 29.79 1047.85 3941 585
500 253.3 37 2.951 20.66 0.7 4.1 30.26 1087.77 4133 605

CABLE AAC 15 kV

Magnitudo Sectio Area Phase Conductor Conductor Diameter Semiconductor Crassitudo Vagina Crassitudo Cable Diameter Proxime.Totalis Pondus Fractio Load Current Capacitas
No.of Threads Diameter filum
(AWG vel kcmil) (mm2) Nec. (mm) (mm) (mm) (mm) (mm) ( kg / km ) ( kgf ) (A)
2/0 67.44 19 2.126 10.63 0.7 3.1 18.23 359.41 1212 270
3/0 85.02 19 2.388 11.94 0.7 3.1 19.54 425.5 1500 310
4/0 107.2 19 2.680 13.4 0.7 3.1 21 506.71 1822 355
266.8 135.2 19 3.010 15.05 0.7 3.1 22.65 607.05 2254 410
336.4 170.5 19 3.381 16.91 0.7 3.1 24.51 722.86 2789 485
477 241.7 37 2.884 20.19 0.7 3.1 27.79 964.38 3941 585
500 253.3 37 2.951 20.66 0.7 3.1 28.26 1002.93 4133 605

CABLE ACSR 15 kV

Magnitudo Sectio Area No.of Threads Diameter filum Conductor Diameter Semiconductor Crassitudo Vagina Crassitudo Aprox.Cable Diameter Proxime.Totalis Pondus Fractio Load Current Capacitas
aluminium Steel aluminium Steel
(AWG vel kcmil) (mm2) Nec. Nec. (mm) (mm) (mm) (mm) (mm) (mm) (kg / km) (kgf) (A)
4 21.15 6 1 2.118 2.118 6.36 0.7 3.1 13.96 206.66 843 135
2 33.62 6 1 2.672 2.672 8.02 0.7 3.1 15.62 280.02 1292 175
1/0 53.49 6 1 3.370 3.370 10.11 0.7 3.1 17.71 390.56 1986 230
2/0 67.43 6 1 3.782 3.782 11.35 0.7 3.1 18.95 465.38 2404 260
3/0 85.01 6 1 4.247 4.247 12.74 0.7 3.1 20.34 557.98 3002 295
4/0 107.2 6 1 4.770 4.770 14.31 0.7 3.1 21.91 672.75 3786 330
266.8 135.19 18 1 3.092 3.092 15.46 0.7 3.1 23.06 671.95 3120 415
266.8 135.19 26 7 2.573 2.000 16.3 0.7 3.1 23.9 798.34 5125 425
336.4 170.45 18 1 3.472 3.472 17.36 0.7 3.1 24.96 812.02 3936 480
336.4 170.45 26 7 2.888 2.250 18.29 0.7 3.1 25.89 970.69 6393 490
397.5 201.41 18 1 3.774 3.774 18.87 0.7 3.1 26.47 933.17 4508 535
397.5 201.41 26 7 3.140 2.440 19.88 0.7 3.1 27.48 1118.43 7393 545
477 241.7 18 1 4.135 4.135 20.68 0.7 3.1 28.28 1089.06 5352 595
477 241.7 26 7 3.439 2.674 21.8 0.7 3.1 29.4 1310.68 8845 610

CABLE ACSR 25 kV

Magnitudo Sectio Area No.of Threads Diameter filum Conductor Diameter Semiconductor Crassitudo Vagina Crassitudo Aprox.Cable Diameter Proxime.Totalis Pondus Fractio Load Current Capacitas
aluminium Steel aluminium Steel
(AWG vel kcmil) (mm2) Nec. Nec. (mm) (mm) (mm) (mm) (mm) (mm) (kg / km) (kgf) (A)
4 21.15 6 1 2.118 2.118 6.36 0.7 4.1 15.96 250.02 843 135
2 33.62 6 1 2.672 2.672 8.02 0.7 4.1 17.62 328.2 1292 175
1/0 53.49 6 1 3.370 3.370 10.11 0.7 4.1 19.71 444.81 1986 230
2/0 67.43 6 1 3.782 3.782 11.35 0.7 4.1 20.95 523.21 2404 260
3/0 85.01 6 1 4.247 4.247 12.74 0.7 4.1 22.34 619.86 3002 295
4/0 107.2 6 1 4.77 4.770 14.31 0.7 4.1 23.91 739.18 3786 330
266.8 135.19 18 1 3.092 3.092 15.46 0.7 4.1 25.06 741.72 3120 415
266.8 135.19 26 7 2.573 2.000 16.3 0.7 4.1 25.9 870.54 5125 425
336.4 170.45 18 1 3.472 3.472 17.36 0.7 4.1 26.96 887.29 3936 480
336.4 170.45 26 7 2.888 2.250 18.29 0.7 4.1 27.89 1048.66 6393 490
397.5 201.41 18 1 3.774 3.774 18.87 0.7 4.1 28.47 1012.83 4508 535
397.5 201.41 26 7 3.140 2.440 19.88 0.7 4.1 29.48 1201.01 7393 545
477 241.7 18 1 4.135 4.135 20.68 0.7 4.1 30.28 1173.95 5352 595
477 241.7 26 7 3.439 2.674 21.8 0.7 4.1 31.4 1398.83 8845 610