AS 1222.2 Aluminium Clad Steel Conductor SC/AC

CATEGORY DOWNLOAD SPECIFICATIONS

Product Details

Product parametri

Applicationem

Filum chalybeum Galvanized possidet aluminium Clad Steel Conductor SC/AC plerumque in regione electrica adhibita ad onera mechanica sustinenda.
Accedit, utendum est in Guidone Wire, supra caput Ground or Static Wire, et Messenger Wire.

Characteres

Minima crassitudo radialis 5% crassitudinis filum diametri altiore adhibetur pro aluminio bracchiorum in ferro, qui hanc tunicam habet.Conductivity eius 20.3% IACS et eius UTS iugis ab 1.27 ad 1.34GPa. In comparatione ad conductores cum ferro galvanizato factae, qui utuntur ferro aluminis ad supplementum, resistentiam electricam inferiorem habent et corrosionem altiorem resistentiam praebent.

stipare

Partus longitudinum determinantur ex consideratione talium factorum sicut dimensiones orum corporis, orum pondera, palmi longitudinis et instrumentorum tractandorum.

Construction

Fila chalybea galvanizata concentrically destituuntur, cum stratum extimum dextera utebatur et strata sequens contrariam laicorum partem habentibus.
Conductor maius filum centrale (filum regis) si necessarium incorporare potest.Haec diameter filum 5% maius est quam in filis propinquis et in consilio conductoris in rebus consistit.

AS-NZS-Aluminium Clad-Steel-(2)

Specifications

AS 1222,2 Standard Aluminium Clad Steel Standard

AS/NZS 1222.2 Standard Aluminium Clad Steel Conductor SC/AC Physical, Mechanical and Electrical Performance Parameters

No./Dia.of Fila Stranding

Nominal Super Diameter

Cross Section Area

Nominal Linear Mass

Fractio Load

Modulus Elasticitatis

Coefficiens Linear Expansion

DCResistance

Continua vena portandi facultatem (A)

ad 20°C

ad 75°C

nocte hieme

meridie aestate

No./mm

mm

mm2

kg/km

kN

GPa

x 10–6/°C

Ω/km

Ω/km

in aere

ventus

ventus

in aere

ventus

ventus

3/2.75

5.9

17.82

118

22.7

159

12.9

4.80

5.75

48

83

97

38

76

90

3/3.00

6.5

21.21

141

27.0

159

12.9

4.02

4.82

54

93

108

42

84

100

3/3.25

7.0

24.89

165

31.6

159

12.9

3.42

4.10

60

103

120

47

93

110

3/3.75

8.1

33.12

220

39.3

159

12.9

2.58

3.09

72

123

143

56

111

131

7/2.75

8.3

41.58

277

50.1

157

12.9

2.06

2.47

81

138

161

63

124

148

7/3.00

9.0

49.48

330

59.7

157

12.9

1.73

2.07

91

154

179

70

138

164

7/3.25

9.8

58.07

387

69.9

157

12.9

1.47

1.76

102

170

198

77

153

181

7/3.75

11.3

77.28

515

86.9

157

12.9

1.11

1.33

123

204

237

92

181

215

7/4.25

12.8

99.33

662

105

157

12.9

0.864

1.04

145

238

277

107

211

251

19/2.75

13.8

112.9

755

136

155

12.9

0.764

0.915

158

259

300

116

228

272

19/3.00

15.0

134.3

899

162

155

12.9

0.642

0.124

178

288

335

129

54

302

19/3.25

16.3

157.6

1060

189

155

12.9

0.545

0.653

200

320

371

142

280

334

19/3.75

18.8

209.8

1410

236

155

12.9

0.411

0.492

244

382

443

172

333

397

19/4.25

21.3

269.6

1800

286

155

12.9

0.320

0.383

291

448

519

203

387

462

ASTM-Galvanized Steel-Strand-3Nota
Notae electricae supra ostensae effectus magneticos in consideratione non accipiunt et ideo tantum approximatae sunt.
Current ratings innituntur sequentibus conditionibus:
• Conductor temperatus supergreditur ambientem 40° C
•Aer ambiens temp.de XXXV ° C ad aestas meridiem vel X ° F in hiemem noctem
• Dirige radiorum solaris intensio M W / m2 pro meridie vel nulla aestate pro nocte hiberna
• diffunde radiorum solaris intensio C W / m2 pro meridie vel nulla aestate pro hieme noctis
• Terrae reflexio 0.2
• Emissio et effusio solaris coefficiens superficiei conductoris, 0.5

Quaere nobis?

Percontatione de instrumentis nostris vel pretio indice, electronicam tuam nobis relinque et intra XXIV horas erimus